NET METERING · HOME / SHOP / FACTORY

Korea only: this calculator uses KEPCO (Korea Electric Power) tariffs in force since June 1, 2026 and the Korean net metering rules. All amounts are in Korean won (KRW).

Solar Net Metering Savings Calculator (Korea: homes, shops and factories)

Net metering savings sheet

※ Net metering rule: Article 18 of the Korean guideline on trading small scale renewable power (credit at the same rate on the meter reading date, surplus carried to the next month) and the KEPCO ON net metering bill calculation method. Fill in the yellow boxes only.

■ 1. Inputs
Monthly input (if summer and winter differ)

Leave blank to use the average in ③ for all twelve months.

Frequently asked questions

What is net metering?

You install solar where you use electricity and send the unused surplus to KEPCO. That surplus is subtracted from the electricity you received from KEPCO that month (Article 18 of the guideline on trading small scale renewable power). Generated electricity is valued at the same rate as the electricity you buy, and the two are netted on the meter reading date. Solar up to 1,000 kW qualifies.

What happens when generation exceeds use?

The remaining credit is subtracted from next month's supply (carried over). You can instead choose to be paid, but that rate is based on the weighted average system marginal price (SMP) for the period, which is often lower than the rate you pay. This calculator uses the carry over method and shows the credit left over at year end separately.

Why is the progressive tier effect so large for homes?

The energy charge is calculated on the energy after netting. A home that used to exceed 450 kWh (July and August) or 400 kWh (other months) and drops to 150 kWh after netting moves from the tier 3 rate (307.3 KRW) to the tier 1 rate (120.0 KRW). In the KEPCO example the demand charge tier follows the energy received before netting, but the page marks that rule as pending, so ⑧ lets you see both.

Why does VAT not fall as much?

As KEPCO explains, VAT is charged on the energy received before netting, so the bill falls more than the VAT does. A business issues a tax invoice for the exported power and files VAT on it, so in the end it carries no VAT burden. For shops and factories the results also show the savings for a VAT registered business.

How is self consumption calculated?

For each of the 8,760 hours the solar output is compared with the load. The smaller of the two is self consumption, and when generation is higher the difference is surplus sent to KEPCO. The hourly shape of the load comes from ②. The two factory profiles are built from a full year of 15 minute KEPCO meter data at two real factories, while the home and shop profiles assume typical living and business hours.

What solar capacity is right?

If a large credit is left over at year end, the system is too big. Surplus is only paid at the SMP rate or carried over, so the best installed cost per saving comes when yearly generation is close to or a little below yearly use. Change ⑤ above and look for the capacity with the shortest payback.

Notes (sources checked 2026-11-11) Not included: module degradation (0.5% per year only in the 20 year total), tariff increases, welfare discounts, splitting a billing month across seasons, whether the power industry fund applies before or after netting (source not confirmed, applied to the charge after netting), cash settlement rate (SMP).