Korean solar permitting setback rules explained
Since September 2026 Korean local governments can only apply house setbacks of up to 200 m and a few zone setbacks to solar. How we measure, count and report them.
How we size ESS for peak shaving with 15 minute data
Korean industrial tariffs bill the highest 15 minute demand for a year. Our method: a full year of KEPCO data, two dispatch models and a capacity sweep.
PVsyst vs Solar Pro cross-check on a 619 kWp roof
Same weather, same module, same 3D scene: the two programs agreed within 2.2% unshaded and 0.24 points on shading loss. What the gap means for finance.
Agrivoltaic structure design basics
Column grid, 4 m clearance, Korean wind and snow codes and a 3D check that changed the column size. A worked agrivoltaic design of about 1 MW.
Electrical BOQ and quantity take-off workflow
From conductor counts per conduit segment to conduit sizes, take-off sheets and a Korean public format BOQ, with a worked example on one floor.
Korea industrial electricity tariff 2026: rates, demand charges and a worked bill
KEPCO industrial rates by class, voltage, option, season and time band in KRW, the billing demand rule, and a full winter bill of 27,347,780 KRW worked line by line.
Solar permitting in Korea: the seven steps, statutory periods and a real timeline
License, development permit, KEPCO connection, pre technical review, construction plan notification, pre use inspection and commencement report, with dates from a 1.35 MW roof.
Net metering in Korea: the Article 18 rules and what changes on the bill
Who qualifies, how exported kWh are credited, the SMP settlement for net export months, KEPCO's worked bill, the application steps and how to size a roof for it.
Korea's agrivoltaics act: who can build, where, for how long, and the draft design rules
Act No. 21804 in force 17 December 2026: eligible operators, farmland rules, 30 year cap, draft 30% shading and 2.5 m height, and the yield of a compliant 986 kWp design.
Peak shaving ESS payback in Korea: a worked example with 2026 tariffs
A 200 kW / 600 kWh battery on the industrial (B) tariff: 25 million KRW a year saved, payback of 12 to 19 years depending on cost, and what shortens it.
P50 and P90 for solar in Korea: how we build a bankable yield estimate
Korean weather sources and their bias, bad station years, the IEA based uncertainty table, and a 496 kWp worked example with P90 at 91% of P50 for one year and 93% for a ten year average.
BESS feasibility study in Korea: what a bankable analysis contains and how we cross check it
The inputs a Korean behind the meter battery study needs, the two dispatch runs, and how HOMER Grid, DER-VET, REopt, SAM and BLAST-Lite compared with our engine on one factory.
Rooftop solar structural review in Korea: loads, anchors, reinforcement and the permits that follow
KDS 41 wind and snow loads, roof zone pressures, rail and clamp pull out, the 7.5 kN anchor check on a 1.35 MW roof, new beams and columns under a major repair permit, and what KESCO asks for at inspection.
Fire alarm and telecom design and BOQ in Korea: separate contracts, detector counts and the quantities that get missed
Why fire and telecom work are contracted apart from electrical in Korea, the NFTC 203 detector area table with worked counts, the tray and interface boundaries, and the items that go missing.
Solar project timeline in Korea: how long each stage really takes, from license to commercial operation
Dated timelines from two factory roofs (1.35 MW through the power exchange in 9.5 months, 558 kW under a KEPCO agreement in 12 months), the statutory day counts, equipment lead times and what runs in parallel.